Tools Required:
• Impact Punch-Down Tool with 110 Blade
Installation:
Align the mounting pins of the Telephone
Module with holes in the back of your
Telecommunication Enclosure and lock
Telephone Module into place.
• Install the cable from the telephone company
demarcation point to the 110 IDC connector
marked LINE IN.
• Install twisted pair cables from each location in
the house to the remaining 110 IDC connectors.
Match the color-coding of the wires to the colors
on the 110 IDC connectors.
• The wires should be punched down to the 110
IDC connectors using an industry standard
punch-down tool. Use the T568A wiring
configuration as shown above.
• Line 1 is Blue, Line 2 is Orange, Line 3 is Green
and Line 4 is Brown.
NOTE: The RJ31x port is used to install the
security line.
CAUTION:
• Never install low voltage wiring during lightning storms.
• Never install low voltage wiring in wet locations unless the wire is specifically designed for wet
locations.
• Never touch un-insulated low voltage wires or terminals unless the wire has been disconnected at its
source.
• Do not use this product near water. For example: near a bath tub, wash bowl, kitchen sink, laundry tub,
in a wet basement or near a swimming pool.
• Consult and comply with local building and electrical codes, before and during installation of any
equipment.
• Never push objects of any kind into this product through cabinet slots as they may touch dangerous
voltages.
• Use caution when installing low voltage cables.
• Read and understand all instructions.
• Save these Instructions.
NOTE: Only Licensed Professionals Should Install this Product.
Instruction / Installation Sheet
1 x 8 Telephone Module
Part # 80-0070
ETL LISTED. CONFORMS TO UL STD 1863 ANSI/UL STD 60950-1 CERTIFIED TO CAN/CSA STD C22.2 NO 60950-1
DataComm Electronics, Inc.
6349 Peachtree Street
Norcross, GA 30071-1725
888.223.7977
770.662.8205
www.DataCommElectronics.com
Wiring Diagram: